Femra · Guide
CLT panels in Femra
Femra analyses cross-laminated timber as a layered panel and checks every layer, from the layup to fire, walls and joints.
The layup
A CLT panel in Femra is a timber material with a layup: an ordered list of layers from the panel's bottom face to its top. Each layer has a thickness, a grain direction (along the panel's main direction or across it), a strength class (C14 to C40, or T14; C24 by default), whether its lamellas are edge-glued, and the lamella width.
You can give the layers one by one, or name a layup from Femra's generic catalogue:
| Layers | Generic layups, total thickness in mm |
|---|---|
| 3 (L3s) | 60, 80, 90, 100, 120 |
| 5 (L5s) | 100, 120, 140, 160, 180, 200 |
| 7 (L7s) | 220, 240, 260, 280 |
| 7 with doubled outer layers (L7s-2) | 220, 240, 260, 280 |
Names follow the form product approvals use: CLT 160 L5s (40l-20w-40l-20w-40l), where l is a layer along and w one across. The generic layups are C24, not edge-glued, with 150 mm lamellas.
Generic or declared. A generic layup uses typical values, and every sheet says so: "generic layup, typical values: check against the product's ETA". For a real product, give its values from its European Technical Assessment (ETA): moduli, strengths such as the rolling shear strength fv,R,k, kdef and γM. Femra supplies no manufacturer's values of its own.
The main direction
Every CLT slab has a main direction: the way its outer layers run, normally the span. Femra asks for it on slabs. Walls take their outer layers vertical unless you say otherwise. The element card shows a panel's main direction and its layup drawn to scale.
From layup to stiffness
Femra turns the layup into a layered, orthotropic shell: stiff along the grain, soft across it, and soft in shear across the cross layers. The finite element analysis uses these stiffnesses directly, element by element, turned to each element's axes.
- Laminate theory gives the membrane stiffness A and the bending stiffness D per metre of width, both ways.
- Cross layers that are not edge-glued get E90 = 0. Their in-plane shear stiffness is reduced for the gaps between lamellas, and the twisting stiffness by the factor the Swedish CLT handbook gives (0.65 with gaps, 0.8 without).
- Transverse shear per direction is the energy-equivalent stiffness of a layered beam, with the low rolling shear modulus (typically 50 MPa) in the cross layers. This is what makes a short, heavily loaded CLT span deflect more than simple beam theory says.
- The shear analogy (Kreuzinger), the method many engineers use by hand, is written beside it on the layup sheet for comparison.
The CLT layup sheet, one per CLT material in use, shows every layer's values and the panel's A, D and shear stiffnesses with the effective values per direction (EIef, EA, GAef) and the mass.
The checks
The basis is EN 1995-1-1 as it applies in Sweden (with BFS 2024:6) and Swedish practice for CLT: the product's ETA and the Swedish CLT handbook (KL-trähandbok). kmod follows the shortest action in each combination, as for solid timber; γM is 1.25 unless the ETA declares another.
| Check | What Femra does | Sheet |
|---|---|---|
| Bending and axial force | Every layer of every element, every ULS combination, at both faces of the layer. | CLT panel |
| Rolling and longitudinal shear | τR in each cross layer, τv in each along layer, and the two together. Peaks at supports are averaged as for concrete slabs. | CLT panel |
| Deflection with creep | Per field between supports: winst and wnet,fin with kdef, against L/300 by default. | CLT deflection |
| Floor vibration | EN 1995-1-1 7.3.3 per floor field, with a plate model of the field for f1 and the deflection under 1 kN. Damping 2.5 % for CLT floors by default. | floor vibration |
| Fire | The char front through the layup (β0 0.65 mm/min), char layers falling off at bond lines unless the ETA says the adhesive holds, gypsum or wood protection, then the checks on the residual section. Up to 120 minutes. | CLT in fire |
| Walls in compression | Vertical strips of at most 1 m between openings, buckling with the rolling shear's softening, bending from wind and eccentric floors; also in fire. | CLT wall |
| Bearing | Walls standing on CLT floors (platform construction) and posts on floors, compression across the grain. | CLT bearing |
| In-plane shear | Walls as shear walls and floors as diaphragms: net shear of the layers, and torsion of the glued crossings. | CLT in-plane shear |
| Openings and point loads | Re-entrant corners read over a small region, lintels and parapets as beams, notches at supports as warnings, posts and columns on floors. | CLT openings and point loads |
| Joints, anchors, screws | Joints between panels as springs in the analysis, hold-downs that lift, angle brackets and hold-downs checked from their ETA, screwed joints (splines, half-laps, corners, wall to floor) checked on the analysis's forces. | CLT joint, CLT anchorage, CLT screw joint |
| Stability | Each wall's share of a storey's horizontal load, overturning, hold-down and toe forces, floors as diaphragms. | Stability |
A panel's utilisation is the largest of its checks. The Design panel lists it, the magnifier opens its sheets as tabs, and the report has a table per check in English or Swedish.
Working with CLT, step by step
- Draw or import the panels. Slabs and walls as panels, from your assistant, from an OpenEik building or from a file.
- Give the material a layup. Ask your assistant for a generic layup ("make the floor a CLT 200 L5s") or give the product's layers and ETA values.
- Set the main direction on each slab, along its span.
- State what the checks need: the service class (1 or 2), the fire requirement and exposed face if any (for example R60 from below), which slabs are floors for the vibration check, and footprints for point loads (a post's plate), so the load is spread as it is in reality.
- Run and check. Open the governing panel's sheets. The CLT panel sheet names the governing element, combination and layer, and shows the layer table.
- Change the layup and run again until every check passes, or try alternatives as variants.
Give a point load a footprint. A load on a single node makes the rolling shear under it grow without bound as the mesh gets finer; spread over the plate it bears on, it is checked as it acts.
Worked example: a CLT floor
Femra's example CLT floor (open it from the examples, or ask your assistant to load the example clt-floor) is a synthetic dwelling floor, built only through the assistant's commands:
- A 200 L5s floor, 4.8 × 4.8 m, spanning 4.8 m between two walls.
- A service shaft 0.8 × 0.6 m near one wall.
- A post from the storey above, 6 kN permanent and 3 kN imposed, on a 200 mm plate.
- Safety class 2, service class 1, R60 from below.
| Check | Utilisation | Governs |
|---|---|---|
| Ultimate limit state, per layer | 0.21 | bending beside the post |
| Deflection with creep | 0.66 | the field between the walls |
| Vibration | 0.90 | the floor field |
| Fire, R60 | 0.16 | residual section |
The example shows a typical pattern for CLT floors: strength is rarely the limit, while deflection and vibration govern the thickness. Its shaft's corners are read over a small region around each corner, so the checked value settles as the mesh is refined instead of growing with it.
The vibration check spreads the field's mass evenly. When heavy items stand on a floor, run a modal analysis of the whole floor as well: a heavy post lowers its first frequency.
CLT from a building and in other programs
- OpenEik and EikHub. A slab or wall type that says CLT becomes a CLT material: from its layers (each layer's grain, where the building states it), or from one core as a generic layup of that thickness. A slab's main direction comes from the building. A layup you change in Femra goes back to the building as a proposed new type, never as an edit of the building's own type.
- FEM-Design
.struxmlcarries the layup both ways as a CLT panel type. - ANSYS APDL gets a layered shell section with the layers' own properties.
- SAF and STAAD.Pro get equivalent plates, with a note and the stiffness ratios.
Limits
- Service classes 1 and 2. Service class 3 is refused for CLT.
- Notches at supports are warnings, not utilisations: the code in force has no rule for notches in CLT.
- The deformation across the grain under walls and posts in service is not computed.
- The fire method covers up to 120 minutes; longer is reported as not covered.
- Unsymmetric layups are not supported.
For how Femra works with your assistant in general, see Femra basics.